How to Setup a Manual Speed Selector Switch (Single-Line SP Drives)

| 0

Solar Drive Manual Speed Selector Switch Setup

In some instances it might be required to have various predefined speed selections for a drive using a manual multi-stage switch. This can be achieved by using an external multi-stage switch connected to the drive’s Multi-Function Terminals and programming the Multi-Function References accordingly.

The following scenario is only applicable to EM12 Series Solar Drives and EM15 Series Solar Drives with Single-Line Keypads – for EM15 Series Solar Drives with Double-Line Keypads (similar parameters as for VSDs), please see the following FAQ entry: VSD Speed Selector Switch

Consider a scenario using a 3-stage switch as per the example below, where the switch selections should reflect speeds of 50% (25Hz), 70% (35Hz) and 100% (50Hz) of the Max speed (50Hz). To achieve this the switch needs to be connected to the Digital Input Terminals of the Drive. Since the Switch selection Option 0 (K2) is always off (only K1 and K2 switches On/Off), only Option 1 (K1) and Option 2 (K2) needs to be connected. In the example below K1 is connected to DI3 and K2 connected to DI4 (thus requiring setting parameters F4-02 and F4-03 accordingly). Based on the Switch Options table below these options thus reflect Multi-Function References 1, 0 and 2 in the below table (thus requiring setting parameters FC-01, FC-00 and FC-02 as a percentage of F0-11). To ensure the Drive acknowledges this setup as the Speed Reference Point for the Drive, also set F0-03 = 6 (Multi-Function). In summary, the following parameters needs to be set:

  • F0-03 = 6 (To set Speed Reference as the Multi-Functions)
  • F4-02 = 12 (To set DI3 Terminal as Multi-Function Terminal 1)
  • F4-03 = 13 (To set DI4 Terminal as Multi-Function Terminal 2)
  • FC-01 = User Defined Value (to set Reference 1 speed value as a percentage of F0-10)
  • FC-00 = User Defined Value (to set Reference 0 speed value as a percentage of F0-10)
  • FC-02 = User Defined Value (to set Reference 2 speed value as a percentage of F0-10)
  • F0-10 = User Defined Value (max speed default = 50Hz)

SP Single-Line Keypad Multi Function Switch

Link to this Page