Keypad Parameters Display Lines Modification
The default parameter display for Double Line Keypads (EM15 VSDs and Solar Drives) can be changed as follows (changing the display parameters for Single-Line Keypads is not possible):
Bottom Keypad Line:
To change the Display for the bottom line use the Shift Key (double right arrow) on the keypad to scroll through all the running parameters. The last parameter on display will be kept as the default display (Please see FAQ Entry HERE for more details on setting this up). When selecting the PRG Key (Programme), this keypad line will allow for scrolling through all the various VSD setting parameters (in order to edit any of the required parameters). The setting parameters list can however also be changed by updating the MF-K (Multi-Function) key function (which by default is set to Forward JOG when pressing and holding the key). To change this, set b9-01 = 5 (Function Parameters) and A0-06 =1 (To allow displaying the Function Parameters). After updating these, whenever the PRG key is pressed, the bottom keypad line will offer three options to select from using the MF-K button as follows:
- BASE: Shows all function parameters
- USER: Shows only the most common user parameters (16 Parameters as follows: b0-01~b0-03; b0-07; b0-08; b0-21; b0-22; b3-00; b3-01; b4-00~b4-02; b5-04; b5-07; b6-00; b6-01)
- C: Shows modified parameters only – shows all parameters which does not equal the default value used by the software
Top Keypad Line:
To change the Display for the top line set parameter b9-11 using the desired value (see list of options below):
- U0-00 Running frequency
- U0-01 Setting frequency
- U0-02 DC Bus voltage
- U0-03 Output voltage
- U0-04 Output current
- U0-05 Output power
- U0-06 Output torque
- U0-07 DI state
- U0-08 DO state
- U0-09 AI1 voltage
- U0-10 AI2 voltage
- U0-11 AI3 voltage
- U0-14 Load speed display
- U0-15 PID setting
- U0-16 PID feedback
- U0-17 PLC stage
- U0-18 Input pulse frequency
- U0-19 Feedback speed, unit:0.01Hz
- U0-20 Remaining running time
- U0-21 AI1 voltage before correction
- U0-22 AI2 voltage before correction
- U0-23 AI3 voltage before correction
- U0-24 Linear speed
- U0-26 Present power-on time
- U0-27 Present running time
- U0-28 Actual feedback speed
- U0-29 Encoder feedback speed
- U0-30 Main frequency X
- U0-31 Auxiliary frequency Y
- U0-32 Viewing any register address value
- U0-34 Motor temperature
- U0-35 Target torque
- U0-37 Power factor angle
- U0-38 ABZ position
- U0-39 Target voltage of V/F separation
- U0-40 Output voltage of V/F separation
- U0-41 DI input state visual display
- U0-42 DO output state visual display
- U0-43 DI function state visual display 1
- U0-44 DO function state visual display 2
- U0-45 Fault information
- U0-46 Phase Z signal counting
- U0-47 Present setting frequency (%)
- U0-48 Present running frequency (%)
- U0-49 Frequency inverter running state
- U0-50 Sent value of point-point communication
- U0-51 Received value of point-point communication